BUILT-IN MUFFLER
Solid metal assembly to reduce noise levels unto 50%.*
REDESIGNED HEAD
Helps compressors run quieter and cooler.
UPGRADED MOUNTS
Equipped with newly designed spring-loaded vibration isolators mounts for added dampening.
Additional Info Download:
Manual
Please Note: Use thread sealant for proper installation. Thread tape is not recommended. Properly sealed, recommended torque for 1/8 is 10 ~ 11 ft. lbs. Recommended torque for 1/4 and 3/8 is 16 ~ 18 ft. lbs.
| Thermal Overload Protector |
| Heavy Duty Pressure Switch (165 PSI on, 200 PSI off) |
| Black Sleeved Stainless Steel Braided Leader Hoses |
| Inline Check Valve |
| 40-Amp 12v Relays |
| Spring Loaded Vibration Isolating Feet |
| Mounting Hardware |
| Air Line for Remote Mount Air Filter |
| Remote Mount 6-Stage Air Filter/Muffler Assemblies |
| (2) Replacement Air Filter Elements |
| Installation Instructions |
| 12-Volt |
| Permanent Magnetic Motor |
| Duty Cycle: 100% @ 100 PSI |
| Duty Cycle: 50% @ 200 PSI |
| Max. Working Pressure: 200 PSI |
| Max. Air Tank Size: 10.0 Gallon |
| Max. 12V Amp Draw: 46-Amps |
| Ingress Protection Rating: IP67 |
| Dimensions: 12.5?L x 4.4?W x 7.3?H |
| Net Weight: 19.5lbs. |
Please Note: Use thread sealant for proper installation. Thread tape is not recommended.
Properly sealed, recommended torque for 1/8 is 10 ~ 11 ft. lbs. Recommended torque for 1/4 and 3/8 is 16 ~ 18 ft. lbs.
| 2.5 Gallon Tank (P/N 91025) |
| 5.0 Gallon Tank (P/N 91050) |
| All Pressure Switches |
| All Pressure Switches w/ Relays |
| All Sealed Pressure Switches |
* For 12V Only.
Please Note: Use thread sealant for proper installation. Thread tape is not recommended. Properly sealed, recommended torque for 1/8 is 10 ~ 11 ft. lbs. Recommended torque for 1/4 and 3/8 is 16 ~ 18 ft. lbs.
| PSI | CFM | A | BAR | LPM | A |
|---|---|---|---|---|---|
| 0 | 2.94 | 30 | 0 | 83.3 | 30 |
| 10 | 2.75 | 32 | 1.0 | 75.2 | 33 |
| 20 | 2.60 | 35 | 2.0 | 71.1 | 35 |
| 30 | 2.48 | 36 | 3.0 | 66.8 | 37 |
| 40 | 2.38 | 37 | 4.0 | 62.5 | 39 |
| 50 | 2.26 | 38 | 5.0 | 59.3 | 40 |
| 60 | 2.17 | 39 | 6.0 | 55.6 | 43 |
| 70 | 2.11 | 40 | 7.0 | 52.0 | 43 |
| 80 | 2.01 | 40 | 8.0 | 49.8 | 43 |
| 90 | 1.93 | 43 | 9.0 | 46.7 | 43 |
| 100 | 1.85 | 44 | 10.0 | 43.3 | 43 |
| 110 | 1.79 | 44 | 11.0 | 41.8 | 43 |
| 120 | 1.73 | 43 | 12.0 | 39.3 | 43 |
| 130 | 1.66 | 43 | 13.0 | 37.3 | 43 |
| 140 | 1.61 | 43 | 14.0 | 34.3 | 42 |
| 150 | 1.51 | 43 | |||
| 160 | 1.47 | 43 | |||
| 170 | 1.44 | 43 | |||
| 180 | 1.35 | 43 | |||
| 190 | 1.31 | 43 | |||
| 200 | 1.25 | 43 |
* Supply Voltage: 13.8 Volts
| 2.5 GALLON TANK | FILL RATE |
|---|---|
| 0 to 145 PSI | 1 min. 30 sec. (± 10 sec.) |
| 110 to 145 PSI | 30 sec. (± 05 sec.) |
| 0 to 200 PSI | 2 min. 25 sec. (± 10 sec.) |
| 165 to 200 PSI | 35 sec. (± 05 sec.) |
| 5.0 GALLON TANK | FILL RATE |
| 0 to 145 PSI | 3 min. 15 sec. (± 10 sec.) |
| 110 to 145 PSI | 1 min. 00 sec. (± 10 sec.) |
| 0 to 200 PSI | 5 min. 00 sec. (± 10 sec.) |
| 165 to 200 PSI | 1 min. 15 sec. (± 10 sec.) |
* Due to redundant restrictions added to apparatus, for flow rate testing, actual flow rate at 0 psi may vary.